ACTIVE-200 – A robust dual-beam active infrared system designed for both outdoor and indoor use, offering an impressive 200-meter detection range. Featuring an infrared transmitter and receiver, the system triggers and illuminates a red LED when beams are crossed. Its water resistance and immunity to external light interference ensure consistent performance, even in challenging environments. Continuous synchronization between components prevents interference, while easy installation is made possible with adjustable units and a signal strength display for precise alignment. This system excels in reliable motion detection, remaining immune to false alarms for unwavering security.
Maximize protection with cutting-edge technology for any environment.
Out door
Wired
SYNCHRONIZED active infrared beams, to eliminate “cheating” the receiver part by a foreign IR transmitter
200 meter effective range
Water resistant
Internal vertical and horizontal alignment
Precise alignment by a built-in scale or externally by connecting a voltmeter
Adjustable beam interruption time
Changeover alarm contacts (N.C. / N.O.)
Power Supply
12V DC
Average Current drain
Transmitter unit - 60 mA; Receiver unit - 30 mA
Sensing element
2 x Beam active infrared
Detection type
Active Barrier
Detection distance
Up to 200 m
Warm-up time
1 minute (approximately)
Alarm contacts endurance
(NC) 15V DC / 20mA
Tamper switch contacts
(NC) 15V DC / 20mA
Alarm time
At least 2 Seconds
Interruption time to cause an alarm
50 to 500 Millisecond
Internal alignment angle adjustment
+/-5°, Horizontal +/-90°
Operating temperature
(-)10°C ~ 60°C (14°F ~ 140°F)
Humidity withstand
95% (Depending on temperature)
Dimensions
2X - 155 x 64 x 62mm (HxWxD)
Weight
190 gr.
SYNCHRONIZED active infrared beams, to eliminate “cheating” the receiver part by a foreign IR transmitter
200 meter effective range
Water resistant
Internal vertical and horizontal alignment
Precise alignment by a built-in scale or externally by connecting a voltmeter
Adjustable beam interruption time
Changeover alarm contacts (N.C. / N.O.)
Power Supply
12V DC
Average Current drain
Transmitter unit - 60 mA; Receiver unit - 30 mA
Sensing element
2 x Beam active infrared
Detection type
Active Barrier
Detection distance
Up to 200 m
Warm-up time
1 minute (approximately)
Alarm contacts endurance
(NC) 15V DC / 20mA
Tamper switch contacts
(NC) 15V DC / 20mA
Alarm time
At least 2 Seconds
Interruption time to cause an alarm
50 to 500 Millisecond
Internal alignment angle adjustment
+/-5°, Horizontal +/-90°
Operating temperature
(-)10°C ~ 60°C (14°F ~ 140°F)
Humidity withstand
95% (Depending on temperature)
Dimensions
2X - 155 x 64 x 62mm (HxWxD)
Weight
190 gr.